This website uses cookies primarily for visitor analytics. Certain pages will ask you to fill in contact details to receive additional information. On these pages you have the option of having the site log your details for future visits. Indicating you want the site to remember your details will place a cookie on your device. To view our full cookie policy, please click here. You can also view it at any time by going to our Contact Us page.

BROWSE PRODUCTS
 

Faster to install than other Rogowski cables

A Rogowski coil solution for the popular EM210MV 3 phase energy meter for retrofit applications has been launched by energy management specialist, Carlo Gavazzi. The ROG4K Rogowski solution which most importantly does not require an external power supply or external integrator makes installations faster and simpler.

This is thanks to the meter’s self-power supply from the voltage reference inputs, automatic phase detection with wrong-phase-sequence warning and fast application-oriented programming procedure.

Current measurements are carried out by means of a ROG4K flexible current sensor which has a hole diameter from 115mm to 275mm and can measure a primary current from 20 to 4000Amps and guarantees Class 1 accuracy.  It includes 3 coils in different colours to simplify the work of the installer and a secondary cable terminal with tag of the same coil colour to simplify and minimize wiring errors.


The EM210MV series offers single phase variables such as THD, Neutral current and hour counter to link the energy consumption to the relevant working hours as well as, compatibility with the CTV versions.  Available in 2 input voltage ranges MV53 or MV63 and 333mV current signal as well as the new Rogowski cables.

The EM210 MV has a selection of variables which can be programmed providing for active and reactive energy measurement or a complete set of 3-phase variables from 6 application options. Options include: system variables such as W, var, PF, Hz and phase-sequence; single-phase variables including A, PF and THD (A, V, up to 15th Harmonic); relevant phase to phase and phase to neutral voltages and phase currents. The THD can be enabled or disabled by the user.  The EM210 can also calculate and display the neutral current instantaneous value.

Available with pulse only or pulse and Modbus output to provide fast and easy data transmission to connect with PC’s, PLC’s BMS or other data acquisition and monitoring systems.

Instantaneous variables are displayed as 3 x 3 digits, with energy meter readings to 7 digits. Accuracy is ±0.5% RDG (V, A), and the meter is rated Class B (kWh) according to EN50470-3 (class 1 of EN62053-21), Class 2 (kvarh) according to EN62053-23.

The EM210 range of 3 phase energy meters replaces the extremely popular family of EM21 energy meters, but utilizes many of its features such as its unique patented detachable display which enables the meter to be mounted either on a front panel with just 72x72mm footprint, or on a DIN-rail in only four modules wide and can be used as either a basic energy or multifunction meter combining simplicity and compactness in an innovative and cost-effective energy meter solution for building management systems and cost allocation.