This website uses cookies primarily for visitor analytics. Certain pages will ask you to fill in contact details to receive additional information. On these pages you have the option of having the site log your details for future visits. Indicating you want the site to remember your details will place a cookie on your device. To view our full cookie policy, please click here. You can also view it at any time by going to our Contact Us page.

BROWSE PRODUCTS
 

PULS UK urges companies to check their redundant power systems

Power supply manufacturer PULS UK is urging companies to look closely at the redundancy back-up systems providing emergency power to mission-critical production equipment.

PULS UK’s Managing Director Harry Moore

PULS believes that many supposedly fail-safe systems are not as secure as operators think.

Common problems affecting redundancy systems include batteries in DC UPS and AC UPS units not functioning correctly. This could either be because their useful life has expired or they are working outside their temperature range; AC UPS or generators that are not sufficiently powerful for the inrush current needed for the system; offline AC UPS systems that appear to be functional but are not; and single fusing of the input circuits of redundant power units.

PULS’s engineers have even seen systems where various components have not been connected or have been wired incorrectly.

“It is on the AC side that we see most mistakes being made, especially when it comes to the correct installation of fuses,” said PULS UK’s Managing Director Harry Moore (pictured). “A typical example happened last year. Two 20-amp power supplies wired in parallel were being used in a redundant system requiring 20 amps. Although the company had fused each of them separately, they had been wired through a single breaker at the junction box. The junction box fuse was higher rated, but the length of the cabling and the power available at the individual power supply fuses meant that the single breaker tripped first, resulting in the redundancy system being rendered useless.”

In this case the problem was soon rectified, but the disruption to production caused by the unnecessary failure proved very expensive.

Production equipment is usually very reliable and in some respects this is part of the reason why redundancy systems are neglected. It’s only when something goes wrong and production grinds to a halt that a fault or design error is found.

Moore added: “I would urge operators to look carefully at their redundancy systems to make sure everything is working correctly. Most production equipment is very reliable, but if the worst happens and the redundancy system is not up to the job, the result can be very expensive.”

If people need help in assessing the integrity of a redundancy system, PULS can arrange for an engineer to visit the site and check that everything is working properly, even if they are not using PULS equipment.


Contact Details and Archive...

Related Articles...

Print this page | E-mail this page

 
Electrical Products