This website uses cookies primarily for visitor analytics. Certain pages will ask you to fill in contact details to receive additional information. On these pages you have the option of having the site log your details for future visits. Indicating you want the site to remember your details will place a cookie on your device. To view our full cookie policy, please click here. You can also view it at any time by going to our Contact Us page.

BROWSE PRODUCTS
 

PRODUCT OF THE WEEK: EMS FireCell System

EMS Group have unveiled a new generation of wireless analogue addressable fire detection systems that use new and innovative radio technology. The FireCell system incorporating Smart Cluster Technology (SCT) is a breakthrough in system design that makes the product fully conform to the latest EN54 part 25 requirements. FireCell uses the European-wide 868Mhz frequency band and new bi-directional multi-frequency communication techniques.

SCT is a cluster radio network that provides a number of unique advantages over traditional wireless fire systems. The fire alarm control panel connects to a multiple frequency Radio Hub that co-ordinates the wireless communication with up to 64 radio clusters. Each cluster can contain up to 32 wire-free smoke detectors, sounders, call points and I/O devices. The control panel can monitor a maximum of 512 devices throughout a building without using expensive fire-rated cable.

The radio devices in each cluster are monitored by a Radio Cluster Communicator (RCC) that also serves as a bi-directional range extender, passing the communications to and from the Radio Hub to the more distant areas, this enables complete building coverage. The RCC does not require a wired link to the control panel. In the unlikely event of a RCC failing, other RCC’s take over the reporting path and maintain communication with the Radio Hub. This arrangement provides a fault-tolerant solution, giving genuine flexibility for the designer and installer. The advanced secure bi-directional communications ensures that even when passing up to four RCC’s, a signal from any device can reach the control panel in 0.5 seconds.

The system’s radio coverage far exceeds the range achieved by other 868Mhz based wireless fire systems. This is achieved by the use of diversity reception, multi-path techniques and the use of multiple frequencies. FireCell’s immunity to radio interference is also minimised by the ability to automatically change operating frequency channels.

FireCell can use compatible analogue addressable fire sensors from either GE/Ziton or Apollo. The fire sensors attach to radio bases that are completely self-contained and internally powered using a dual supply from low-cost alkaline batteries. When the batteries are approaching the end of their useful life, ample warning is given to allow the replacement of the batteries within a reasonable timescale.

The operation and capability of FireCell’s control panel with cause-and-effect functions will be familiar to anyone who uses conventional multi-loop analogue addressable systems. This allows the engineers current experience with traditional systems to be used as the basis for programming the FireCell wireless system. A simple procedure allows all the clusters of devices to be logged onto the system via the Radio Hub. An automatic configuration process then allocates the most appropriate frequency channels for the location and tests the integrity of the radio network. Cabling faults often found during commissioning of hard-wired fire systems are eliminated.

During the life of the system, buildings may be refurbished or changes made and devices can easily be repositioned moving from cluster to cluster to suit the new requirements.